Specifications; Features; Installation Options; Heating Specifications - Lopi Direct Vent Freestanding Stove Owner's Manual

Direct vent freestanding stove, natural gas or propane, vent horizontally or vertically, standard residential, mobile home approved
Table of Contents

Advertisement

6

Features:

-
Ember Fyre™ Burner for "Wood Fire" Look
-
Works During Power Outages (millivolt system)
-
High Efficiency
-
Optional Thermostat or Remote Control
-
Optional Blower for Quicker Heat Distribution
-
Convenient Operating Controls
-
Variable-Rate Heat Output
-
Low Maintenance

Heating Specifications:

Approximate Heating Capacity (in square feet)*............up to 850 with Blower, up to 650 Without
Maximum Input (in BTU's) .........................................................................18,000
Minimum Output On Low (in BTU's)...........................................................9,900
Steady State Efficiency............................................................................up to 80.1%
AFUE (without blower) .............................................................................Up to 67.8%
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature.
* *
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system.
Dimensions & Weight:
Electrical Specifications (for optional blower)
Electrical Rating.........................................................115 Volts, 1.3 Amps, 60 Hz (150 watts on high)
Fuel:
This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using
the included LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel.
Travis Industries

Specifications

NOTE:
Measure side, corner,
and back clearances
from the stove top.
14"
24-1/2"

Installation Options:

The flue collar protrudes 2-7/8"
behind the stove top
Weight: 130 Lbs.
1 0 0 - 0 1 1 4 2
-
Freestanding Stove
-
Horizontal or Vertical Vent
-
Residential or Mobile Home
-
Straight or Corner Placement
-
Bedroom Approved
20-3/4"
18-1/2"
4 0 5 0 1 1 4