Heating Specifications:
Approximate Heating Capacity (in square feet)*....................................600 to 1,600
Maximum BTU Input Per Hour.............................................................38,500 NG
BTU Input on Low..............................................................................18,700 NG
Efficiency .......................................................................................81 % NG
AFUE................................................................................................72.4% NG
*
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature.
* *
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system. To measure the net BTU's, multiply the BTU input by the efficiency percentage.
Dimensions
The starter section
is 4-1/8" below the
upper top.
Measure Clearances
from the Upper Top
Fuel:
This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using
the included LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel.
Electrical Specifications
Electrical Rating (with optional blower)......................115 Volts, 0.8 Amps, 60 Hz (92 watts on high)
Travis Industries
Specifications
Features:
•
•
•
•
•
24"
4-7/8"
18-3/4"
4041220
Ember Fyre ™ Burner for "Wood Fire" Look
Works During Power Outages
Variable-Rate Heat Output
Optional Thermostat or Remote Control
Variable-Speed Blower
Weight: 205 Lbs.
Pedestal: 34-7/8"
Cast Legs: 30-7/8"
5
36,500 LP
18,000 LP
81.5 % LP
73 % LP
1 0 0 - 0 1 1 5 3