Finalizing the Installation
Finalizing the Installation
!
Make sure the gas control valve is "OFF" and the heater is cool prior to conducting service.
1 Remove the glass (see page 19)
2 Install the log set and coals (see page 21).
!
We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3 Replace the glass (see page 19)
4 Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.
5 Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
Travis Industries
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Standard
Screwdriver
1 0 0 - 0 1 1 4 2
(for qualified installers only)
4 0 5 0 1 1 4
1 7