Installation Hints; Stove Clearances; Mobile Home Requirements - Lopi Direct Vent Freestanding Stove Owner's Manual

Direct vent freestanding stove, natural gas or propane, vent horizontally or vertically, standard residential, mobile home approved
Table of Contents

Advertisement

Installation
8

Installation Hints:

If converting to LP, convert the appliance prior to installation.
The blower is easiest to install prior to installation. Because the blower is located near the gas inlet
location, we recommend using the included pipe and elbow to route the gas inlet around the blower
position.
Install the logs last - they are fragile.
When determining the location of the stove, locate the wall studs (for horizontal penetrations) and
ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure
the vent does not intersect with a framing member.
Fumes and smoke from the paint curing and oil burning off the steel may occur the first time you start
this heater. This is normal. We recommend you open windows to vent the room.

Stove Clearances

Straight Installations
3-1/2" Min.

Mobile Home Requirements

When the stove is installed in a mobile home, it must be bolted to the floor.
When the optional blower is installed it must be connected to a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from the optional blower cord.
Travis Industries
(for qualified installers only)
4-3/4" Min.
1 0 0 - 0 1 1 4 2
Corner Installations
1" Min.
1" Min.
45°
4 0 5 0 1 1 4

Hide quick links: