Safety (Listing) Label - Lopi Direct Vent Freestanding Stove Owner's Manual

Direct vent freestanding stove, natural gas or propane, vent horizontally or vertically, standard residential, mobile home approved
Table of Contents

Advertisement

3 0
The safety (listing) label is on the back of the stove. A copy of the safety label is shown below.
Report No. 028-S-50-5
Tested to: ANSI Z21.88b-2001 "Vented Gas Fireplace Heater" and UL 307b-1995 "Gas Burning Heating Appliances
for Manufactured Homes".
VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas
Code, ANSI Z223.1.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP)
is desired, the optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an after-
market, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's
manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the owner's information manual provided with this appliance. For assistance or additional infor-
mation consult a qualified installer, service agency or the gas supplier.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting sys-
tem or tampering with the blocked vent shutoff system can result in carbon monoxide (CO) poisoning and possi-
ble death.
CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s)
should be done by a licensed or qualified service person.
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids hav-
ing flammable vapors away.
This appliance must be properly connected to a venting system in accordance with the manufacturer's installa-
tion instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior
manual for approved brands of venting.
Input Rate on "HI" (BTU/Hr)* . . . . . . 18,000 18,000
Input Rate on "LO" (BTU/Hr)* . . . . . 14,600 14,100
This appliance is equipped only for altitudes 0-2000 ft. (0-610 m).
Electrical Rating: 115v, 1.5 Amps, 60 Hz
Manufacture
Date:
Travis Industries
Safety Label
Certified for USA
Minimum Clearances to Combustibles
Stove Top to Sidewall ......................... 3.5"
Stove Top to Backwall ........................ 4.75"
Stove Top to Cornerwall.....................
Glass Front of Unit.............................. 36"
L.P.
2002
Jan.
2003
Feb.
2004
Mar.
Sturbridge
Vented Gas
Fireplace Heater
. See owner
Alcove Min. Height....................................
Alcove Max. Depth ....................................
1"
Alcove Min. W idth..................................... 27.75"
N.G.
Minimum Inlet Pressure (inches W.C.) . . . . . . . .
Manifold Pressure on "HI" (inches W .C.) . . . . . .
Apr.
Jul.
Oct.
May
Aug.
Nov.
Jun.
Sep.
Dec.
1 0 0 - 0 1 1 4 2
's
36"
48"
L.P. N.G.
11"
5.5"
10"
3.5"
10850 117th Pl. N.E. Kirkland, WA 98033
IGN 0466
4 0 5 0 1 1 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sturbridge