Approved Vent Config's Vertical Term; Natural Gas - Lopi Direct Vent Freestanding Stove Owner's Manual

Direct vent freestanding stove, natural gas or propane, vent horizontally or vertically, standard residential, mobile home approved
Table of Contents

Advertisement

Installation
Approved Venting Configurations with a Vertical Termination
Remove the diffuser plate (see "Diffuser Plate Removal" on page 12)
Two 90° elbows or two 45° offsets may be used (after the initial 90° elbow)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

Natural Gas

31' (max)
30 feet
25 feet
20 feet
15 feet
10 feet
5 feet
0 feet
Travis Industries
Restrictor Position # 7
Remove Diffuser Plate
31' (max)
30 feet
25 feet
Restrictor Position # 5
Remove Diffuser Plate
20 feet
15 feet
10 feet
5 feet
0 feet
1 0 0 - 0 1 1 4 2
(for qualified installers only)
Propane (LP)
31' (max)
30 feet
25 feet
20 feet
15 feet
10 feet
5 feet
0 feet
1 5
Restrictor Position # 6
Remove Diffuser Plate
31' (max)
30 feet
25 feet
Restrictor Position # 5
Remove Diffuser Plate
20 feet
15 feet
10 feet
5 feet
0 feet
4 0 5 0 1 1 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sturbridge

Table of Contents