Specifications; Installation Options; Features; Heating Specifications - Lopi Heritage-2000 Owner's Manual

Table of Contents

Advertisement

Installation Options:

Freestanding Stove
Residential or Mobile Home
Horizontal or Vertical Vent

Heating Specifications:

Approximate Heating Capacity (in square feet)*......1,200 to 2,000 With Blower, 800 to 1,600 Without
Maximum BTU Input Per Hour ...............................43,000 (NG & LP)
Minimum BTU Output on Low (with blowers on) .....23,384 (NG) 20,800 (LP)
Steady State Efficiency............................................................................up to 78% (NG), 81% (LP)
AFUE......................................................................................................71% (NG), 73.7% (LP)
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature.
* *
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system. To measure the net BTU's, multiply the BTU input by the efficiency percentage.

Dimensions:

Fuel:

This heater is shipped in
natural gas (NG)
configuration but may be
converted to propane (LP)
using the included LP
conversion kit. The sticker
on top of the gas control
valve will verify the correct
fuel.

Electrical Specifications

Electrical Rating .........................................................115 Volts, 0.8 Amps, 60 Hz (92 watts on high)
Travis Industries

Specifications

Features:

The starter section is 1-1/4"
above the top.
32-3/8"
9 3 5 0 8 1 2 1
Ember Fyre ™ Burner for "Wood Fire" Look
Works During Power Outages
Optional Thermostat or Remote Control
Variable-Rate Heat Output
Blower Standard
8-1/4"
20-3/8"
Weight: 275
Lbs
27-3/8"
Measure
Clearances
from the
Stove Top
2 3 1 0 0 0
5