Lopi Patriot Owner's Manual

Lopi Patriot Owner's Manual

Wood-burning stove
Hide thumbs Also See for Patriot:
Table of Contents

Advertisement

P a t r i o t
Wood Stove
Owner's Manual
Freestanding Stove
Mobile-Home Approved
Alcove Approved
Hearth-Stove Approved
Save these instructions
for future reference
6

Advertisement

Table of Contents
loading

Summary of Contents for Lopi Patriot

  • Page 1: Safety Notice

    P a t r i o t Wood Stove Owner's Manual Freestanding Stove Mobile-Home Approved Alcove Approved Hearth-Stove Approved Save these instructions for future reference SAFETY NOTICE:...
  • Page 2 Introduction Introduction Important Information Mail your Warranty Card Today, and Save Your Bill of Sale.
  • Page 3 Table of Contents Maintaining Your Appliance General Information Stove Installation INSTALLATION DIAGRAMS Warranty Operating Your Appliance Listing Information Optional Equipment Index...
  • Page 4 ASHES 36" Type Clay Liner...
  • Page 5 Mobile Home This Manual...
  • Page 6 The 6" diameter flue collar is 4-1/8" from the back edge of the stove top. 23-5/8" Note: Measure side, corner, and back clearances from the stove top. 14-5/8"* 26-1/2" Weight: 270 Lbs. * Distance from faceplate to rear edge of stove top...
  • Page 7 Attach each leg to the stove by inserting a bolt and washer through the hole or slot in the leg and into the threaded hole on the stove. 9/16" Socket Wrench These rubber-tipped bolts are for leveling the stove. Make sure they contact the floor. Do not adjust with weight on the legs, the rubber tips may tear.
  • Page 10 Chimney Cap (See the section "Chimney Termination Minimum System 15' Requirements" for Maximum System 33' more details) Roof Penetration Equipment (Roof Radiation Shield, Factory Built Flashing, Storm Collar) Chimney Sections Floor Penetration Minimum Air Space to Equipment (Attic Combustibles (See Radiation Shield with Chimney Manufacturer's Chimney Support)
  • Page 11 Chimney must extend 2' Slanted Roofs above any portion of the roof Chimney must within 10' of the chimney extend 3' above the roof Chimney must extend 2' above any portion of the roof Flat Roofs within 10' of the chimney Chimney must extend 3' above the roof...
  • Page 12 Non-combustible alcove construction (on walls and ceiling) - see the explanation above. Ventilated air space 3 1/2" thick non- combustible material 1" Min. Non-combustible reinforcer...
  • Page 13 STRAIGHT CORNER INSTALLATION INSTALLATION NOTE: Measure rear clearances from the edge of the stove top, not the rear heat shield. 12” Min. Connector Clearance (as outlined above) Stove Clearance (as outlined above)
  • Page 14 Chimney Cap (See the section "Chimney Follow the chimney Termination Requirements" manufacturer's instructions for more details) and clearances for roof penetrations. A storm collar and flashing are required Chimney Sections (some require a radiation shield). Insulation Follow the chimney manufacturer's instructions Minimum Air Space to and clearances for floor Combustibles (See...
  • Page 15 Chimney Cap Follow the chimney (See the section "Chimney manufacturer's Termination Requirements" instructions and for more details) clearances for roof penetrations. A storm Chimney Sections collar and flashing are required (some require Minimum Air Space to Combustibles (See a radiation shield). Chimney Manufacturer's Wall Bands Minimum 15'...
  • Page 16 NOTE: The e ntire fireplace, including chimney, must be clean and not cracked or damaged. Flue Liner Any damage must be repaired prior to installation of the insert. Stainless steel Chimney must be at least 15' tall chimney connector and no greater than 33' tall. must Extend 1' past Entire fireplace, including the block-off plate...
  • Page 17 2 to 4 hours Rotate the door Swing handle. the door open.
  • Page 19 Use the air control to change the burn rate. Low Burn High Burn (air control closed) (air control open) ASHES...
  • Page 20 HIGH Turn the dial all the way counter- The high position is all the way counter- Turn the dial all the clockwise until it clicks off. clockwise, without clicking off. way clockwise. BLOWER BLOWER BLOWER CONTROL CONTROL CONTROL Creaks and Clicks: The steel may creak or click when the stove heats up and cools down - this is normal.
  • Page 21 Wood Wood Leads Leads Less More Heat Heat Leads Leads More Smoke Less Smoke and Creostoe and Creostoe Cut wood to length and Store the wood off the ground in a chop into quarters. covered area. Allow for airflow Air Flow around the wood to dry the wood.
  • Page 23 ASHES Allow the stove to fully cool. Apply glass cleaner or soapy water to the inside of the glass. Wipe with newspaper or a paper towel. For Stubborn Creosote: Dip newspaper or a paper towel in cool ashes and wipe it on the glass. The ash acts as a light abrasive.
  • Page 24 Use wood stove gasket High-Temperature anti-sieze cement to re-adhere may be used on the door loose gasket. hinges to eliminate squeaks. Severely frayed or thread-bare If the glass is damaged, replace it - see “Replacement Parts” for gasket should be replaced. details.
  • Page 25 Touch-Up P a i n t BOTTOM OF Use a vacuum cleaner to remove any STOVE buildup on the screens of the blower.
  • Page 26 1/8” Hex Wrench # 20 Torx Driver NOTE: Place the glass gasket around the perimeter of the door retainer. 9/16" Wrench NOTE: Glue the door gasket to the door retainer.
  • Page 27: Maintaining Your Appliance

    Maintaining Your Appliance Firebox Parts ID # Description Part # ID # Description Part # Floor and Side Firebrick Removal & Replacement Do not pry firebrick - they chip and crack easily.
  • Page 28 All three air tubes are identical. Air Tube Collar Air Tube Remove the left pin on the air tube collar Roll Pin Slide the air tube to the left, swing it down and remove from the firebox.
  • Page 30 ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Maximum alcove depth 48”, minimum alcove height 84”, minimum alcove width 59-5/8" (Patriot) 60” (Parlor). MOBILE HOME INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Mobile home installations also require outside air - use the Lopi optional outside air boot.
  • Page 31 These wires pass Control through the left side convection channel. Insert the thermodisk Thermodisk Bend metal up or down assembly 4" to 5" inside Assembly here to create a snug fit the convection channel. Feed the two snap disk wires into Use a screwdriver to the eye of the wire clip.
  • Page 32 Use a Bottom of Stove screwdriver to pry out the Attach the included knock-out (if applicable). gasket to all four top edges of the air boot. Attach the air boot with the two screws included with the kit. 1/4" Nutdriver Use the included screws to attach the two telescoping portions of air boot together.

Table of Contents