Testing Procedures; Component Testing Procedures - Amana AGR5712BD Series Service Manual

30” freestanding gas ranges
Table of Contents

Advertisement

Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.

Component Testing Procedures

Illustration
Oven light socket
Manual latch
assembly with
switch
(select models)
Rocker switch
Door lock switch
NC
NO
COM
Bake burner
Broil burner
Ignitor
Temperature sensor
Pressure regulator
Shutoff valve
Safety valve
Spark ignition
electrode
14
!
Component
Measure voltage at oven light ....................
Remove one wire from receptacle and
test resistance of terminals ........................
Disconnect wires and test for continuity
per wiring diagram ..................................... See wiring diagram for schematic layout.
Measure continuity of switch positions:
Closed....................................................
Open ......................................................
Switch connection in following positions: ...
Not engaged...........................................
Engaged.................................................
Verify gas is supplied.
Verify proper orifice installed-Nat or LP .....
Check for obstructions, contamination
in ports or damage.....................................
Verify gas is supplied.
Verify proper orifice installed-Nat or LP .....
Check for obstructions, contamination
in ports or damage.....................................
Test for voltage at terminals.......................
Test for amount of amperage in circuit.......
(Ignitor may glow, but not have sufficient
amperage to open valve.)
Measure resistance ................................... Approximately 1000 Ω at room
Verify gas pressure (WCP) ........................
If using LP service, verify proper gas
supply conversion.
Verify gas supply is turned on....................
Adjust set screw for simmer control.
Disconnect wiring to valve.
Measure resistance on bake circuit ...........
Measure resistance on broil circuit ............
Test for resistance of spark lead................
Test ignitor to chassis ................................
WARNING
Test Procedure
16026785
Results
120 VAC, see wiring diagram for terminal
identification.
Continuity with bulb inserted.
If voltage is not present at oven light,
check wiring or light switches.
Refer to Parts Manual for replacement
components.
NOTE: If latched is moved to LOCK
position during Bake or Broil, the control
cancels the function.
Continuity
Infinite
Normally Open
COM – NO = Open, COM – NC = Closed
COM - NO = Closed, COM - NC = Open
Air shutter opening: .469" to .531".
Blue flame with no yellow tipping.
Replace if punctured or torn.
Air shutter opening: .281" to .343".
Blue flame with no yellow tipping.
Replace if punctured or torn.
120 VAC
3.2
3.6 Amps.
to
°
temperature 80
F.
4
Natural
"
10
LP/Propane
"
Gas ON: ..... Slot at 9 o'clock position
Gas OFF: ... Slot at 12 o'clock position
Continuity
Continuity
Do not attempt to open valve with
120 VAC.
Continuity
No continuity from ignitor to chassis.
© 2005 Maytag Services

Advertisement

Table of Contents
loading