Amana AGR5712BD Series Service Manual page 18

30” freestanding gas ranges
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
M1 Diagnostic Code Checking
Code
1c1c
Shorted key
1c31
Cancel key circuit problem
1c4c
Micro communication failure
1c5c
Vcc or ground
1c6c
EEPROM error
1c7c
Control not calibrated
1c8c
Cooking program error
1d11
Runaway temp (650° F), door unlocked
1d21
Runaway temp (950° F), door locked
3d11
Sensor open
3d21
Sensor shorted
4d11
Door position switch not closed when door locked
4d51
Door switch circuit failure-neither open or closed
9d11
Latch will not lock
9d21
Latch will not unlock
9d31
Unlock state unknown, both locked and unlocked
9d41
Unlock state unknown, neither locked or unlocked
M1 Diagnostic Code Handling
Code
1c1c
Keypress
1c31
Cancel key improper value
1c4c
Checksum invalid
1c5c
Vcc/Gnd at test point
1c6c
No response from EEPROM
1c7c
Calibration value out of range
1c8c
CRC invalid
1d11
Sensor resistance > 2293 Ohms
1d21
Sensor resistance > 2662 Ohms
3d11
Sensor resistance > Infinite Ohms
3d21
Sensor resistance > 0 Ohms
4d11
Door switch not closed when door locked
4d51
Door switch not open or closed
9d11
Lock switch not closed (Clean activated)
9d21
Lock switch closed (Clean not activated)
9d31
Unlock switch both locked and unlocked
9d41
Unlock switch neither locked or unlocked
9d51
Lock switch not locked or unlocked
18
!
Description
Measurable
WARNING
When Checked
Always
Always
Serial communications
Cook or clean active
Cook or clean active
Always
Cook or clean active
Latch unlocked
Latch locked
Cook or clean active
Cook or clean active
Clean active
Always
Latch should be locked
Latch should be unlocked
Always
Always
What is
Displayed
Disables audible for key depression
Nothing
Disables key
Nothing
Disables all outputs
Nothing
Disables all outputs
Nothing
No action
Nothing
Disables all outputs
Nothing
No action
Nothing
Cancels active cook functions
Nothing
Disables all outputs
Nothing
Disables all outputs
Disables all cook functions for cavity
2
BAKE flashes
Disables all cook functions for cavity
2
BAKE flashes
Nothing
Disables Clean function
2
LOCK flashes
Disables Clean function
Ignore soil level selection, disables clean
2
LOCK flashes
Disables cooking functions
LOCK on steady
No action
Nothing
No action
Nothing
Disables Clean function
Nothing
16026785
Detection
1 minute
1 minute
5 tries
1 minute
5 tries
5 seconds
5 tries
5 seconds
5 seconds
5 seconds
5 seconds
1 minute
1 minute
1 minute
1 minute
1 minute
1 minute
Action Taken By Control
1
1
1
4
3, 4
5
5
5
5
© 2005 Maytag Services
5

Advertisement

Table of Contents
loading

Table of Contents