Amana AGR5712BD Series Service Manual page 69

30” freestanding gas ranges
Table of Contents

Advertisement

Conversion Instructions, Non Self-Clean Models
5. Place the corresponding orifice hood on the burner
fitting according to figure 4. Turn the orifice hood
clockwise by hand approximately one turn. Tighten the
orifice hood clockwise with a ò² socket wrench
approximately 2ò turns.
6. Replace the burner assembly in the main top and
rotate one-eighth turn clockwise using the burner
wrench until the burner locks in place with the igniter
aligned with the reference mark on the main top.
7. Repeat steps 3 through 6 until all orifice hoods have
been changed.
7.2K BTU NATURAL (BLUE)
REPLACE WITH ORIFICE (BLUE)
STAMPED .0310 FOR LP
9.2K BTU NATURAL (NO COLOR)
REPLACE WITH ORIFICE (NO COLOR)
STAMPED .0335 FOR LP
FRONT OF MAINTOP
qŒ o‚~‚Š‰‚W
Replace burner assembly in main top and rotate
approximately one-eighth turn clockwise using burner
wrench until burner locks into position with ignitor aligned
with reference mark on main top.
ORIFICE HOOD
cfdrob R
© 2005 Maytag Services
9.2K BTU NATURAL (NO COLOR)
REPLACE WITH ORIFICE (NO COLOR)
STAMPED .0335 FOR LP
12K BTU NATURAL (RED)
REPLACE WITH ORIFICE (RED)
STAMPED .0350 FOR LP
ART. #9215-250-1
cfdrob Q
^† p…’‘‘‚
a. The approximate length of the flame of oven burner is
a 1/2 inch distinct inner blue flame, figure 6.
cfdrob S
b. Oven burner flame can be checked as follows:
1. Yellow flame on burner - open burner air shutter to
the widest opening that will not cause the flame to lift
or blow off the burner when cold. (See #2 on figure
7.)
2. Distinct blue flame but lifting - close burner air
shutter to the point where it will not cause the flame
to lift or blow off the burner when cold. (See #2 on
figure 7.)
3
LOCK
SCREW
1
ORIFICE
HOOD
c. The oven burner air shutter adjustment is the same on
ranges with a gas pilot or electric ignition.
d. Sealed burner adjustment. Adjust burner air shutter to
the widest opening that will not cause the flame to lift or
blow off the burner when cold according to figure 8.
klqbW Correctly adjusted sealed burners, can have
flames that will lift or blow without a pot over the burner.
These should be adjusted with a pot in place.
AIR SHUTTER
NATURAL POSITION
cfdrob U
16026785
AIR SHUTTER
2
cfdrob T
AIR SHUTTER
LP POSITION
C–7