Conversion Instructions, Non Self-Clean Models - Amana AGR5712BD Series Service Manual

30” freestanding gas ranges
Table of Contents

Advertisement

Conversion Instructions, Non Self-Clean Models

*DV &RQYHUVLRQ
d‚‹‚~‰
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it is adjusted for at the
factory. To convert the unit to either Natural gas or LP
gas will require the replacement of the orifice hoods, and
the adjustment of the air shutters on the burners and
adjustment of the appliance pressure regulator converter
cap.
Inlet pressure to the appliance pressure regulator should
be as follows for checking the appliance pressure
regulator setting:
fkibq mobpprob fk
fk`ebp lc t^qbo `lirjk
Minimum
Maximum
© 2005 Maytag Services
^‰†~‹€‚ m‚’‚ o‚„’‰~‘Œ `Œ‹“‚†Œ‹
The unit appliance pressure regulator must be set to
match the type gas supply used. If converting from
natural gas to LP gas, the appliance pressure regulator
must be converted to regulate LP gas. If converting from
LP gas to natural gas, the appliance pressure regulator
must be converted to regulate natural gas.
The regulator can be accessed from behind the range,
under the cooktop.
To convert the appliance pressure regulator from one gas
to another, remove cap and forcibly snap out plastic
plunger from bottom of cap. Turn plunger over and
forcibly snap back in original location (Figure 1).
k^qro^i
im
d^p
d^p
klqbW Plunger jrpq snap into position; the gas type
5
11
you are converting to must be visible on lower side of
14
14
plunger.