Component Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
31823701
31722801
31986601 − B ˘ B lack
31986602 − W ˘ W hite
31986603 − C ˘ B isque
31938901
1200 W
31939001
1500 W
31939101
2000 W
32054701
− Dual Ribbon
32007001
32064302
−120 VAC
31926701
−240 VAC
31926702
−240 VAC
32064702−240 VAC
31954301
32078201
31967101
31967302
36-32090201-0
!
Component
Oven light socket
Remove one wire from receptacle
and test resistance of terminals.
Measure voltage at oven light.
Oven indicator
Remove one lead from switch
light
terminal and measure resistance
and
across terminals.
Surface indicator
Measure voltage at indicator light.
light
Rocker switch
Measure continuity of switch
positions:
Closed
Open
Ribbon radiant
Remove one wire lead from element
elements, limiters
and measure resistance of the
are not
element.
replaceable.
Verify supply voltage
Warming zone
Remove one wire lead from element
element
and measure resistance of the
element.
Verify supply voltage........................
Infinite switch
Remove wiring from terminals H1
and H2. Connect Volt ohms meter to
H1 and H2.
Measure the following for voltages at
LO, MED, HI:
H1 to H2
Oven temperature
Measure resistance.
sensor
Control limit
Normally Closed
Verify proper operation.
Closed ............215°F .....................
Open...............245°F .....................
Bake element
Disconnect wire leads to element
and measure resistance of terminals.
Measure voltage at bake element.
Broil element
Disconnect wire leads to element
and measure resistance of terminals.
Measure voltage at broil element.
WARNING
Test Procedure
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light, check
wiring or light switches.
Switch closed: 0
Switch open: Infinite resistance
If voltage is present and light does not
operate. Replace light.
If no voltage is present at indicator light
check wiring.
Continuity, if not replace.
Infinite, if not replace.
Continuity, if not replace.
240 VAC
Continuity, if not replace.
120 VAC
LO
MED (4-5)
HI
240 VAC, if not replace switch.
Approximately 1100
75
If open at room temperature, replace.
Continuity
Infinite
Continuity, approximately 20
if not replace.
240 VAC, see wiring diagram for terminal
identification.
If no voltage is present at bake element
check wiring.
Continuity, approximately 19
if not replace.
240 VAC, see wiring diagram for terminal
identification.
If no voltage is present at broil element
check wiring.
2
Results
1200W: 44 to 49
Ω Approximately
1500W: 36 to 40
Ω Approximately
2000W: 26 to 30
Ω Approximately
2500W: 20 to 23
Ω Approximately
100W:
to
Ω Approximately
Time On
Time Off
5%
95%
50%
50%
100%
0%
at room temperature
F.
º
,
,
October 2001