Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
NSC Control Diagnostic Code Checking
Code
1c1c
Shorted key
1c31
Cancel key circuit problem
1c4c
Micro communication failure
1c5c
Vcc or ground
1c6c
EEPROM error
1c7c
Control not calibrated
1c8c
Cooking program error
1d11
Runaway temp (650° F)
3d11
Sensor open
3d21
Sensor shorted
NSC Control Diagnostic Code Handling
Code
Measurable
1c1c
Keypress
1c31
Cancel key improper value
1c4c
Checksum invalid
1c5c
Vcc/ground at testpoint
1c6c
EEPROM error
1c7c
Calibration value out of range
1d11
Sensor resistance > 2218 Ohms
3d11
Sensor resistance > Infinite Ohms
3d21
Sensor resistance > 0 Ohms
NSC CONTROL NOTES:
1
"Action Taken" applies as long as the condition exists. If the condition goes away, the control recovers.
2
If there is a cook function or timer active, the function continues. The user cannot edit the function, and [Cancel] will cancel the cook
mode.
3
Flash rate: 0.2 seconds on, 0.1 second off. Pressing any key will clear the display until the fault clears and is re-triggered.
© 2005 Maytag Services
!
WARNING
Description
What is Displayed
BAKE flashes
BAKE flashes
16026785
When Checked
Always
Always
Serial communications
Cook active
Cook active
Always
Cook active
Always
Cook active
Cook active
Disables audible for affected key depression
Nothing
Disables all outputs
Disables lights and timers
Nothing
Disables all outputs
Nothing
Disables all outputs
Nothing
No action
Nothing
Disables all outputs
Nothing
No action
Nothing
Return to idle; disables all outputs
Disables all cooking functions
3
Disables all cooking functions
3
Detection
1 minute
1 minute
5 tries
1 minute
5 tries
5 seconds
5 tries
5 seconds
5 seconds
5 seconds
Action Taken By Control
1, 2
1
1
1
1
21