Download Print this page

Component Testing Procedures - Amana ACS3350AB Technical Information

Slide-in gas range

Advertisement

Component Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
31823701
Oven light socket
31986601
Rocker switch
31933003
Limits
31933004
31933401
Autolatch assembly
with door plunger
switch
0315960 5 K btu
270° valve
0315961 9 K btu
0315962 12 K btu
0316572
Spark 270° switch
0316773
Spark ignition
electrode
Top surface burner
0315769 5 K btu
0315768 9 K btu
0315767 12 K btu
31962701
Spark module 4 + 0
L
A
B
N
A1
B1
31968201
Temperature sensor
31716501
Bake burner
RT2310015 Rev. 0
!
Component
Remove one wire from receptacle and
test resistance of terminals..................
Measure voltage at oven light ..............
Measure continuity of switch positions:
Closed..............................................
Open ................................................
Oven limit
Closed..............................................
Open ................................................
Fan limit
Closed..............................................
Open ................................................
Disconnect wires and test for
continuity per diagram.
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
Verify gas is supplied.
Orifice adjusted for Natural or LP.
Adjust set screw for simmer control.
Test for voltage at terminals ................
Disconnect wiring and check for
continuity in LITE position....................
Test for resistance of spark lead .........
Test ignitor to chassis..........................
Verify gas is supplied ..........................
Verify burner cap is positioned
correctly.
Test for voltage at terminals L and N...
Check polarity and ground...................
Measure resistances ...........................
Verify gas is supplied.
Orifice adjusted for Natural or LP ........
Check for obstructions or
contamination in ports .........................
WARNING
Test Procedure
2
Results
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring or light switches.
Continuity, if not replace.
Infinite, if not replace.
See wiring diagram.
210°F
240°F
155°F
115°F
NC
NC
COM
L1 L2
NO COM
M
120 VAC
Lock/Unlock
Door
Motor
Switch
Switch
120 VAC
Continuity in LITE position.
Continuity
No continuity from ignitor to chassis.
Check for obstructions in burner ports.
120 VAC
See wiring diagram
Approximately 1100 Ω at room
temperature 75°F.
Set for Natural Gas from the factory
Adjust as necessary.
Replace if punctured or torn.
November 2001
NO

Advertisement