8.11.3 Replacing the motor / gearbox coupling
CAUTION: Danger of crushing!
The motor / gearbox unit is very heavy. Danger of injury to the hands!
● Pay attention to the heavy weight.
Requirements:
● 10 mm socket wrench
Uninstalling the motor / gearbox coupling:
●
Uninstall the motor / gearbox unit, as described in chapter 8.11.1.
●
Use the 10 mm socket wrench to loosen and remove the self-securing nut (4).
●
Remove the carriage bolt, which secures the sealing ring (2).
●
Carefully bend the sealing ring apart and remove it.
WARNING!
Danger of damage to the wheelchair if the coupling is not serviced correctly.
● Be careful not to damage the coupling mechanism during maintenance work.
●
Carefully pull the motor (3) and the gearbox (1) apart.
●
Remove the component parts of the coupling.
●
If necessary replace the coupling.