Repair Work; General Warning Information On Installation Work; Replacing The Drive Motor - Invacare Lynx Service Manual

Hide thumbs Also See for Lynx:
Table of Contents

Advertisement

6

Repair Work

6.1

General warning information on installation work

CAUTION: Risk of damage to the vehicle! Collisions can be caused if shim rings are
removed from the drive wheels during installation work!
• Shim rings are frequently placed between the drive shaft and the wheel hub to compensate
tolerances. Collisions can be caused if these shim rings are removed and not re-installed!
Please install all shim rings in exactly the same positions they were in before dismantling.
6.2

Replacing the drive motor

Note:
When disassembling, note the position of small parts such as screws and washers. Put small
parts down so that they can be reassembled in the right sequence.
Note:
When connecting the motor and magnetic brake cable, ensure that the plug is in the right
position. The motor rotation direction will be reversed if the connection is wrong.
Requirements:
• Open spanner, 13 mm.
• Phillips screwdriver
• Rubber hammer
From the operating manual:
Loosen rear wheel fixing bolts.
Remove the seat
Remove the battery pack.
Remove the drive unit.
Further work:
Support the drive unit with a wooden wedge.
15