Toshiba T4400SXC Maintenance Manual page 31

Toshiba t4400sxc personal computer maintenance manual
Table of Contents

Advertisement

Step 3 Test Program and Replacement Checklist
The HDD test program is stored in the T4400SXC Diagnostics Disk. Perform all of the HDD
tests in the Diagnostics Hard Disk Drive Test. If an error is detected during the HDD test, an
error code and status will be displayed; perform Check 1. The error code and status are
described in table 2-4. If an error code is not generated, the HDD is operating properly.
Refer to part 3, Test and Diagnostics for more information about the HDD test program.
Table 2-4 Hard disk drive error code and descriptions
Code
Status
01h
Bad command
02h
Bad address mark
04h
Record not found
OSh
H DC not reset
07h
Drive not initialize
09h
DMA boundary error
OAh
Bad sector error
OBh
Bad track error
10h
ECC error
11h
ECC recover enable
20h
HDC error
40h
Seek error
BOh
Time out error
AAh
Drive not ready
BBh
Undefined
CCh
Write fault
EOh
Status error
FOh
Not sense error (HW. code=FF)
Check 1
Replace the HDD unit with a new one following the instructions in part 4,
Replacing T4400SXC Field Replaceable Units. If the HDD is still not functioning
properly, perform Check 2.
Check 2
Replace the system board with a new one following the instructions in part 4,
Replacing T4400SXC Field Replaceable Units.