Ignition Control Module Inspection; Ignition Coil Inspection - Honda VT600C Shadow VLX Service Manual

Hide thumbs Also See for VT600C Shadow VLX:
Table of Contents

Advertisement

I G N ITION SYSTEM
I G N ITION CONTROL MODULE
I N S P ECTION
Remove the left side cover and connector plate .
N OTE
Check the system components and lines step-by-step ac­
cording to the troubleshooting chart on page 1 6-3.
Disconnect the ignition control module connectors and check
them for loose o r corroded termi nals.
Measure the resistance between connector terminals using
the following chart.
<6P CONN ECTOR>
ITEM
Ignition primary coil
D C power supply circuit line
< 4 P C O N N ECTOR>
ITEM
I g n ition pulse generator coil
I G N ITION COI L
I N S PECTI O N
Remove the fuel tank ( page 4-3) a n d crankcase breather tank.
Measure the primary coil resistance of the front ignition coil in
the frame.
Remove the right side cover and rear ignition coil and measure
the primary coil resistance.
Checking for continuity between the primary terminals.
0
STANDARD : 1 .89 - 2 .32
Disconnect the spark plug caps from the plugs and measure
the secondary coil resistance with the spark plug caps in place.
STANDARD : 23 . 5 5 - 30.45
1 6 -4
TERMI NALS
8 1
Y and
( Rear) Bu!Y and
8 1
) ,
(+) and G (-
Bu/Y (+) and G (
(-) with the ignition switch " O N " and engine stop
switch " R U N "
TERMINALS
W/Y and Y ( Front) W/Bu and Bu ( Rear)
Each terminal and body ground
(20 ° C/68 ° F)
k O
(20° C/68 ° F)
81
( Front)
-
,
)
Y (+) and G
STANDARD ( 2 0 ° C/68 ° F)
(}
1 . 89 - 2 . 3 2
Battery voltage should come.
STANDARD ( 2 0 ° C/68 ° F)
(}
450 - 550
NO CONTI N U ITY