4.3.5 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks. (Any red/amber
will do during the 5 blinks).
The LED color will be changed as following:
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 blinks) 
red/amber (5 blinks)  solid green

4.3.6 Skip AUTO.BAS

TSPL2 programming language allows user to download an auto execution file to flash memory. Printer
will run the AUTO.BAS program immediately when turning on printer power. The AUTO.BAS program
can be interrupted without running the program by the power-on utility.
Please follow the procedures below to skip an AUTO.BAS program.
1. Turn off printer power.
2. Press the FEED button and then turn on power.
3. Release the FEED button when LED becomes solid green.
The LED color will be changed as following:
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 blinks) 
red/amber (5 blinks)  solid green
30