1. Gap / black mark sensor calibration
2. Gap / black mark sensor calibration,
Self-test and enter dump mode
3. Printer initialization
4. Set black mark sensor as media
sensor and calibrate the black mark
sensor
5. Set gap sensor as media sensor and
calibrate the gap sensor
6. Skip AUTO.BAS

4.3.1 Gap/Black Mark Sensor Calibration

Gap/black mark sensor sensitivity should be calibrated at the following conditions:
1.
A brand new printer
2.
Change label stock.
3.
Printer initialization.
Please follow the steps below to calibrate the gap/black mark sensor.
1.
Turn off the power switch.
2.
Hold on the button then turn on the power switch.
3.
Release the button when LED becomes red and blinking. (Any red will do during the 5
It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order:
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 blinks) 
red/amber (5 blinks)  solid green
Notes:
1. Sensor calibration can be done by Diagnostic Tool or by power on utility. Please
2. Please select gap or black mark sensor type prior to calibrate the sensor.
The LED color will be changed as following pattern:
LED color
blinks).
refer to "3.3 Diagnostic Tool" Section for more information.
Amber
Red
Amber
(5 blinks)
(5 blinks)
Release
Release
25
Green
Green/Amber
Red/Amber
(5 blinks)
(5 blinks)
(5 blinks)
Release
Release
Release
Solid green
Release