Set Black Mark Sensor As Media Sensor And Calibrate The Black Mark Sensor; Set Gap Sensor As Media Sensor And Calibrate The Gap Sensor - Wasp WPL304 User Manual

Hide thumbs Also See for WPL304:
Table of Contents

Advertisement

WPL 304 User Manual
Printer configuration will be restored to defaults as below after initialization.
Speed
Density
Label Width
Label Height
Sensor Type
Gap Setting
Print Direction
Reference Point
Offset
Tear Mode
Peel off Mode
Cutter Mode
Serial Port Settings
Code Page
Country Code
Clear Flash Memory
IP Address
4.3.4 Set Black Mark Sensor as Media Sensor and Calibrate the Black Mark
Sensor
Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks. (Any
green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber
blinks)

4.3.5 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks. (Any
Parameter
127 mm/sec (5 ips) (203DPI)
76 mm/sec (3 ips) (300DPI)
8
4" (101.5 mm)
4" (101.5 mm)
Gap sensor
0.12" (3.0 mm)
0
0,0 (upper left corner)
0
On
Off
Off
9600 bps, none parity, 8 data bits, 1 stop bit
850
001
No
DHCP
-
-
red (5 blinks)
amber (5 blinks)
-
red/amber (5 blinks)
Default setting
-
green (5 blinks)
-
solid green
32
-
green/amber (5

Advertisement

Table of Contents
loading

Table of Contents