LIST OF NECESSARY MATERIALS/TOOLS

Additional hardware and miscellaneous supplies are needed for installation. These items are field supplied and must
be sourced before installation. This list also includes tools needed for installation.
LIST OF MATERIALS/TOOLS
Personal protective equipment/safety devices
Supply/return grilles
Field-fabricated sleeves (if necessary)
5/16" diameter anchor/carriage/lag bolts
7/8" diameter washers
Caulking materials
Miscellaneous hand and power tools and jobsite or
shop materials
Lifting equipment with the necessary capacity and
rigging to safely move/install the systems
Electrical supplies
-
Two (2) 20A circuit breakers for the shelter DC
power plant (one per wall-mount unit)
-
One (1) 5A circuit breaker for the shelter DC
power plant (for the Bard-Link
-
Two (2) various size circuit breakers for
the shelter AC breaker box (see Table 1.1:
Electrical Specifications on page 15)
-
High-voltage wire of various gauges (see Table
1.1)
-
Communication wire: 2-wire, 18 gauge,
shielded with drain
-
18 gauge non-shielded wire for connecting
smoke detector (and hydrogen detector and/or
generator, if applicable) to controller
-
CAT 6 Ethernet cable of field-determined length
(for remote communication, if applicable)
D
36
A
2
MODEL
SERIES
CAPACITY
36 – 3 Ton
42 – 3½ Ton
48 – 4 Ton
60 – 5 Ton
A – Right Hand
L – Left Hand
REVISION
PLC
VOLTS & PHASE
A – 230/208-60-1
B – 230/208-60-3
Manual 2100-620A
Page
8 of 107
controller)
TM
FIGURE 1.1
D-Series DUAL-TEC™ Wall-Mount Unit Model Nomenclature
P
A
05
4
KW
05 – 5 KW
06 – 6 KW
-48VDC
09 – 9 KW
Free Cooling
10 – 10 KW
Unit
-
Miscellaneous electrical supplies including
rigid/flexible conduit and fittings, junction
boxes, wire connectors and supports
The following are required and must be sourced
prior to installation of these units.
• Two (2) 20A circuit breakers for the shelter DC
power plant (one per wall-mount unit)
• One (1) 5A circuit breaker for the shelter DC
power plant (for the Bard-Link
Circuit breakers for Emerson Network Power (ENP)
power plants (used in most telecomm shelters built
today) are available directly through the following
distributors:
• Emerson Network Power: 440.288.1122
• Master Electronics: 888.473.5297 or
www.onlinecomponents.com
Emerson Network Power (ENP) Part Numbers
• 20A circuit breaker: P/N 101601
• 5A circuit breaker: P/N 101598
Always confirm the application before ordering.
P
X
X
X
J
COIL OPTIONS
X – Standard
3 – Phenolic Coated Evaporator and
SPECIAL FEATURES
COLOR OPTIONS
X – Beige
1 – White
4 – Buckeye Gray
FILTER OPTIONS
P – 2-Inch Pleated (MERV 8)
M – 2-Inch Pleated (MERV 11)
controller)
TM
CONTROL MODULES
J – High Pressure Switch, Low Pressure
Switch, Compressor Control Module,
Low Ambient Control, Alarm Contacts,
Start Assist
C – J Module + Compressor Crankcase
Heater
Condenser