Image 7-155
9. Press ENTER
A white bullet indicates the active setting
7.9.7.4
Dynacolor adjustment
Overview
•
Introduction
•
Calibration for the standard mode (for multiple projectors)
•
Common color values
•
Calibration for the Infitec mode (on one projector)
•
Infitec common color values
7.9.7.4.1
Introduction
Although DynaColor can also be used in case of a single projector to force a desired color reproduction, we
will cover only the case where multiple projector have to be color matched using DynaColor.
Standard Dynacolor adjustment procedure (multiple projectors)
The adjustment of Dynacolor consists of :
1.
Measuring the color values for each projector (Calibration procedure)
2.
Calculating the common values filling them in the desired value of every projector
Infitec Dynacolor adjustment procedure (in the projector)
The adjustment of Dynacolor for Infitec consists of :
1.
Measuring the color values for each filter (Calibration procedure) in Infitec mode
2.
perform filter Matching the common values will be filled in automatically by the projector
The Infitec Dynacolor calibration can also be done over multiple projectors. Common values must be calcu-
lated and filled in every projector.
In case one uses linked Dynacolor, the master projector will calculate the common values and force them on
all (the linked) slave projectors
R59770122 BARCO GALAXY NH-12 04/05/2011