HP 6000 330s Owner's Manual page 159

Mass storage system
Table of Contents

Advertisement

HP Series 6000
Models 330S and 660S
Setting the SCSI Address Switches
The address switches on the back of your mass storage
system are for hard disk drives only.
Make sure your CD-ROM drive is set to a unique SCSI
address relative to the other devices on the SCSI bus. The
mass storage system will not function properly if two
devices in the mass storage system have the same SCSI
address.
The SCSI-ID switches (see Figure 4-5) enable you to
select a unique SCSI address for the CD-ROM drive. The
SCSI-ID switches are set to address 0 at the factory, so all
of the switches should be in the down (0) position when
you take the CD-ROM drive out of the anti-static bag.
To set the SCSI-ID switches to a different address before
installing the CD-ROM drive, perform the following steps:
1. Verify that the PRTY and ARBT switches are set to 1,
and the TEST switch is set
to
O.
2. Set the SCSI switches 1, 2, and 3 to 0 or 1 for the
desired address (refer to Table 4-2 and Figure 4-5).
To set the SCSI-ID switches to a different setting after the
CD-ROM drive has already been installed, perform the
following steps:
1. Set the mass storage system
(LiNE-)
switch to the 0 (out)
position.
2. Disconnect the power cord from the mass storage system
rear panel.
CD-ROM Drive 4-23