Hear Rate Grip Replacement - Vision Fitness S70-02 Service Manual

Table of Contents

Advertisement

5.21 Heart Rate Grip Replacement
1) Remove the 2 screws going upward into the top of the heart rate grip (Figure A).
2) Once the 2 screws are removed, pull apart the top and bottom portions of the heart rate grip (Figure B).
FIGURE A
3) Disconnect the heart rate plate wiring and remove the old HR grip (Figure C).
4) Reverse Steps 1-3 to install a new HR grip. NOTE: The white wire should be plugged into the bottom heart rate plate, the red wire on the top. Also
make sure that the end cap gets installed (Figure D).
FIGURE C
5) Test the Elliptical for function as outlined in Section 5.22.
CHAPTER 5: PART REPLACEMENT GUIDE
FIGURE B
FIGURE D
47