Kyocera Mita KM-1500 Service Manual page 72

Hide thumbs Also See for KM-1500:
Table of Contents

Advertisement

2DC
Code
C3200
Exposure lamp problem
(A3200*)
• In indicator check before starting
copying, the average value in scan-
ning of the shading plate with the
CCD is 128 or more.
C3300
Optical system (AGC) problem
(A3300*)
• After AGC, correct input is not ob-
tained at CCD.
C4000
Polygon motor synchronization
(A4000*)
problem
• The polygon motor does not reach
the stable speed within 15 s of the
START signal turning on.
C4010
Polygon motor steady-state problem
(A4010*)
• The polygon motor rotation is not
stable for 5 s after the polygon motor
rotation has been stabilized.
C4200
BD steady-state problem
(A4200*)
• The MIC detects a BD error for 600
ms after the polygon motor rotation
has been stabilized.
"A" is displayed on the market.
1-5-10
Contents
Causes
Check procedures/corrective measures
Defective scanner
Replace the scanner board (KP-5063) and
board (KP-5063).
check for correct operation.
Defective expo-
Replace the exposure lamp or inverter
sure lamp or in-
board.
verter board.
Incorrect shading
Adjust the position of the contact glass
position.
(shading plate). If the problem still occurs,
replace the scanner home position sensor.
Poor contact of
Check the connection of connector YC-6
the connector ter-
on the scanner board (KP-5063), and the
minals.
continuity across the connector terminals.
Repair or replace if necessary.
Insufficient expo-
Replace the exposure lamp or inverter
sure lamp lumi-
board.
nosity.
Defective scanner
Replace the scanner board (KP-5063) and
board (KP-5063).
check for correct operation.
Incorrect shading
Adjust the position of the contact glass
position.
(shading plate). If the problem still occurs,
replace the scanner home position sensor.
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine board (KP-5061) and
board (KP-5061).
check for correct operation.
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine board (KP-5061) and
board (KP-5061).
check for correct operation.
Defective laser
Replace the LSU.
diode.
Defective polygon
Replace the LSU.
motor.
Defective main
Replace the main board (KP-5060) and
board (KP-5060).
check for correct operation.
Remarks