Item
Section
No.
Fixing and
U161 Setting the fixing control temperature
cleaning
U162 Stabilizing fixing forcibly
U163 Resetting the fixing problem data
U199 Checking the fixing temperature
Operation
U200 Turning all LEDs on
panel and
U203 Operating DP separately
support
U207 Checking the operation panel keys
equipment
U243 Checking the operation of the DP motors
U244 Checking the DP switches
Mode setting
U252 Setting the destination
U254 Turning auto start function on/off
U255 Setting auto clear time
U258 Switching copy operation at toner empty detection
U260 Changing the copy count timing
U265 Setting the destination specifications
U332 Setting the size conversion factor
U342 Setting the ejection restriction
Image
U402 Adjusting margins for printing
processing
U403 Adjusting margins for scanning an original on the contact glass
U404 Adjusting margins for scanning an original from the DP
Others
U901 Checking/clearing copy counts by paper feed locations
U903 Checking/clearing the paper jam counts
U904 Checking/clearing the service call counts
U905 Checking/clearing counts by the DP
U908 Checking the total count
U910 Clearing the black ratio data
U911 Checking/clearing copy counts by paper size
U927 Clearing accounting counter
U990 Checking/clearing the time for the exposure lamp to light
U991 Checking the scanner count
U993 Outputting a VTC-PG pattern
* Initial setting for executing maintenance item U020
Maintenance item contents
• Primary stabilization fixing temperature
• Secondary stabilization fixing temperature
• Copying operation temperature 1
• Copying operation temperature 2
• Number of sheets for fixing control
2DC
Initial
setting*
125
135
180
195
5
Europe
On
90
Single mode
After ejection
0
1.0
On
1-4-3

Advertisement