Removing The Laser Scanner Unit And The Eraser Lamp - Kyocera Mita KM-1500 Service Manual

Hide thumbs Also See for KM-1500:
Table of Contents

Advertisement

1-6-11 Removing the laser scanner unit and the eraser lamp

1. Remove the scanner unit (See page 1-6-27).
2. Remove each two screws and then remove
two grounding plates.
3. Remove each two screws and then remove
the right and left scanner stays.
Screws
Right scanner stay
4. Remove four connectors.
5. Remove six screws and then remove the LSU
shield.
* When refitting the LSU shield, tighten a
screw in order of 4 from 1.
Left scanner stay
Figure 1-6-31 Removing the right and left stays
Connectors
Screws
Screws
4
3
Screw
Figure 1-6-32 Removing the LSU shield
Grounding plates
Screw
LSU shield
2
1
2DC
Screws
Screws
1-6-29