Gap/Black Mark Calibration, Self-Test And Dump Mode - Wasp WPL304 User Manual

Hide thumbs Also See for WPL304:
Table of Contents

Advertisement

WPL 304 User Manual

4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode

While calibrate the gap/black mark sensor, printer will measure the label length, print
the internal configuration (self-test) on label and then enter the dump mode.
gap or black mark sensor, depends on the sensor setting in the last print job.
Please follow the steps below to calibrate the sensor.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do
during the 5 blinks)
The LED color will be changed as following order.
Amber
blinks)
It calibrates the sensor and measures the label length and prints internal settings,
then enters the dump mode.
Note:
Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE command prior to
calibrate the sensor.
For more information about GAP and BLINE command, please refer to WPL programming
manual.
-
-
amber (5 blinks)
red (5 blinks)
-
red/amber (5 blinks)
-
green (5 blinks)
-
solid green
28
To calibrate
-
green/amber (5

Advertisement