Planning
Regular Timing (UPLINK)
Regular Timing period in seconds. Every "Regular Timing" seconds, an error checking packet
will be transmitted during normal operation.
If "Regular Timing"=0, no checking is performed.
Otherwise, "Regular Timing" should be in the range of 1 to 999.
The default setting for this value is 0 seconds.
Error Detect Timing (UPLINK)
Error Detect period in seconds. Every "Error Detect Timing" seconds, an error checking packet
will be transmitted during link failure.
"Error Detect Timing" should be in the range of 1 to 999.
The default setting for this value is 3 seconds.
Generally, "Error Detect Timing" should be smaller than "Regular Timing" because more
frequent checking is required when the link is down.
Disconnect on Errors (UPLINK)
During Regular Timing checking, if "Disconnect on Errors" times bad packets are detected
then "link failure" is declared. Regular Timing checking is halted, and Error Detect checking
is started.
"Disconnect on Errors" should be in the range of 1 to 100.
The default setting for this value is 10 times.
Reconnect on Errors (UPLINK)
During Error Detect checking, if "Reconnect on Errors" times good packets are detected then
"normal link" is declared. Error Detect checking is halted, and Regular Timing is started.
"Reconnect on Errors" should be in the range of 1 to 100.
The default setting for this value is 1 times.
Call Control
Use the Call Control section of the worksheet to record parameters associated with Gateway-
to-Gateway and Gateway-to-Gatekeeper communications and for control for the KX-
TDA0480.
The start and signalling port parameters designate the signalling ports on which
communication will be initialised and on which transmission will take place, respectively.
As a rule, the default values should be used.
38