Removing and Replacing Components

Accessing a Pedestal Mounted Server

To extend the server from the rack, perform the following steps:
Step
1. Remove the T-25 screws that fasten the server to the rack. See Figure 7-1, "Accessing 25MM Torx Screws."
Step
2. Flip out the two pull handles at either end of the front bezel and slowly pull the unit forward by the handles. The
server is fully extended when the rail clips are locked in place. When fully extended, the front and top covers are
fully accessible.
Figure 7-1
Accessing 25MM Torx Screws

Insert the Server into the Rack

To insert the server into the rack, perform the following steps:
Step
1. Press the rail clips on either side of the server inward and push the server into the rack until it stops.
Step
2. Replace the T-25 screws that fasten the server to the rack.
Accessing a Pedestal Mounted Server
The hp Integrity rx4640 Server is also designed to be pedestal mounted. You do not need to remove the pedestal from the HP
Server to gain access to internal components. The front bezel, front cover, and top cover may be removed with the pedestal
attached to the HP Server.