CAUTION
Step 10. Plug in the processor cable to its socket on the extender board.
Step 11. Place the sequencer frame over the processor.
Step 12. Using the supplied torx T15 driver, tighten the 6, T15 shoulder screws until they just bottom out. Follow the
tightening sequence shown in Figure 4-11, "Installing Processor on Extender Board Example."
CAUTION
Step 13. Replace the extender board into the chassis.
Step 14. Replace the front cover.
Step 15. Replace the front bezel.
Chapter 4
When rotating the locking cam, hold the palm of your hand on top of the assembly and exert light
pressure. This ensures that the assembly stays flush and level to the socket while it is being
tightened.
Do not overtighten the 6 shoulder screws—they may shear off if overtightened. Stop tightening
the shoulder screws when you feel them just bottom out.
Installing Additional Components and Configuring
Installing Processors and Memory