Replacing The Quickfind Diagnostic Board - HP Integrity rx4640 Operation And Maintenance Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

Removing and Replacing Components
QuickFind Diagnostic Board
Step
3. Gently squeeze the cover surrounding the QuickFind diagnostic board and remove the cover/board assembly from
the top of the power supply cage.
Step
4. Turn this assembly upside down and remove the QuickFind diagnostic board from the cover.
Step
5. Unplug the cable from the connector on QuickFind diagnostic board and remove the board from the chassis.

Replacing the QuickFind Diagnostic Board

To replace the QuickFind diagnostic board, perform the following steps:
Step
1. Gently plug the cable into the QuickFind diagnostic board connector.
Step
2. Replace the QuickFind diagnostic board into the cover by snapping it into place.
Step
3. Turn the assembly over and snap into place on top of the power supply cage.
Step
4. Replace the top cover.
Step
5. If rack mounted, slide the HP Server into the rack until it stops.
220
Chapter 7

Advertisement

Table of Contents