Soft Switch: #22; Soft Switch: #23 - Konica Minolta bizhub 160f Service Manual

Hide thumbs Also See for bizhub 160f:
Table of Contents

Advertisement

16. Soft Switch Set (bizhub 160f/bizhub 161f only)
16.8.22

SOFT SWITCH: #22

Bit
Designation
No.
8
Detect busy tone
before dial
7
Regard dial tone
as busy tone after
dialing
6
Check busy tone
method
5
Reserved
4
CED signal output
level
3
2
1
16.8.23

SOFT SWITCH: #23

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
Reserved
4
Reserved
3
Reserved
2
Reserved
1
Reserved
200
1: Check busy tone within dial tone detection
0: Not to check
1: Yes - Check dial tone after dialing
0: No
0: Measure tone by input energy over threshold
1: By PTT regulation tone frequency
Reserved
Level (dBm)
Bit 4
Bit 3
Bit 2
Bit 1
Level (dBm)
Bit 4
Bit 3
Bit 2
Bit 1
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Confidential – for internal use only, do not distribute
Field Service Ver. 1.0 Apr. 2005
Function
-17 -16 -15 -14 -13 -12 -11 -10
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
-9 -8 -7 -6
-5 -4 -3 -2
1
1
1
1
1
1
0
0
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
Function
Initial
Setting
Bit
HEX
0
0
0
0
0
0
6
1
0
0
1
1
1
1
1
0
0
1
1
1
1
1
1
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
0
0
0
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 161Bizhub 161fBizhub 160

Table of Contents