Soft Switch: #21 - Konica Minolta bizhub 160f Service Manual

Hide thumbs Also See for bizhub 160f:
Table of Contents

Advertisement

Field Service Ver. 1.0 Apr. 2005
16.8.21

SOFT SWITCH: #21

Bit
Designation
No.
8
NSS signal before
DCS
7
CNG duration after
dialing(T1)
6
5
T4 timer
4
Reserved
3
DIS signal length
2
Increase default T1
timing during calling
1
• Bit 1 to 2:T1 indicates the calling time after dialing, can adjust the T1 time longer by
changing the default value. The default T1 timer depends on each country reg-
ulation.
• Bit 3
:Some old machines can not accept DIS command over 4 bytes, and every time
will become fail. In this case you can set this bit to 1. If this bit is set to 1, JBIG
and V8 capability will be disabled automatically.
• Bit 6 to 7:A fax to be received is cancelled and the machine becomes unable to receive it
if the setting of "No. of RINGS" is made longer than the setting of "CNG dura-
tion after dialing." Be sure to make the "No. of RINGS" setting to a value shorter
than the "CNG duration after dialing" setting.
☞ Utility Mode/ RX operation/ No. of RINGS
• Bit 8
:Sender machine's name will show on the other party's LCD or print on the
report if remote side is the same model.
Confidential – for internal use only, do not distribute
16. Soft Switch Set (bizhub 160f/bizhub 161f only)
Function
0: Not to send NSS signal if remote side is same
1: Send NSS signal if remote side is same model
Duration (sec)
40
Bit 7
0
Bit 6
0
0: 3.0 sec – Normal case
1: 4.5 sec
Reserved
0: Normal length (bit 1 to 64)
1: 4 bytes DIS command – bit 1 to 32 only
Description (sec)
T1
Bit 7
0
Bit 6
0
model
60
70
120
0
1
1
1
0
1
T1+ 30
T1+ 40
T1+60
0
1
1
1
0
1
Initial
Setting
Bit
HEX
1
C
1
0
0
0
0
0
0
0
199