Field Service Ver. 1.0 Apr. 2005
B. PRN MAIN REGIST
Functions
• To vary and adjust the print start position in the main scanning direction.
Use
• If the image on the copy deviates in the main scan direction
• When the PH unit has been replaced
Adjustment
Specification
Adjustment
If the width of A is less than the width of B..... Increase the setting.
Instruction
If the width of B is less than the width of A..... Decrease the setting.
Adjustment
1. Print the test pattern.
Procedure
2. Check the amount that widths A and B in the test pattern are shifted.
If the shift is out of specification, adjust it according to the following procedure.
3. Enter the "ADJUST" menu in the Service mode.
4. Change the setting.
If the shift cannot be adjusted to within the specification with a single adjustment, per-
form the adjustment again to change the setting.
5. Press the Yes key to apply the setting.
NOTE
• If the Stop key is pressed, instead of the Yes key, the main screen is displayed
and the setting returns to that before it was changed.
6. Print a test pattern again and check it.
Confidential – for internal use only, do not distribute
13. Service Mode (bizhub 160f/bizhub 161f)
•Adjust the amount that widths A and B in the
printed test pattern are shifted so that the fol-
B
lowing specification is met.
Specifications
0 ± 2.0 mm
A
Setting Range
60 to 140 (1 increment = 0.1 mm)
1382D011AA
The default setting is "100"