4
Disassembly/Assembly > Fixing System > Removing the Fixing Assembly > Procedure

Fixing System

Layout Drawing

[6]
[5]
[4]
[3]
[2]
No.
Name
Main Unit
[1] Fixing Assembly Main Unit
(Refer to page 4-46) -
[2] Fixing Film Unit
Fixing Assembly -
[3] Temperature fuse Fixing Assembly -
[4] Fixing Heater
Fixing Assembly -
[5] Thermistor
Fixing Assembly -
[6] Fixing Pressure
Fixing Assembly -
Roller
4
Disassembly/Assembly > Fixing System > Removing the Fixing Assembly > Procedure
[1]
F-4-112
Reference
Adjastment during
Remarks
parts replacement
-
-
-
-
TP
-
H1
-
TH1
-
-
T-4-21

Removing the Fixing Assembly

■ Preparation

1) Remove the Left Cover.(Refer to page 4-13)
2) Remove the Reader Unit.(Refer to page 4-20)
3) Remove the Right Cover.(Refer to page 4-14)
4) Remove the Front Cover Unit.(Refer to page 4-15)
5) Remove the Upper Cover.(Refer to page 4-15)
6) Remove the Rear Cover.(Refer to page 4-17)
7) Remove the Main Controller PCB.(Refer to page 4-34)

■ Procedure

CAUTION:
• Be sure to perform the operation after the Fixing Assembly is surely cooled because
the assembly right after printing is hot.
• Do not disassemble the Fixing Assembly in the field because it needs adjustment.
1) Remove the Main Controller PCB Installation Plate [1].
• 1 Screw (with washer) [2]
• 2 Screws (black TP) [3]
• 1 Hook [4]
x3
[4]
4-46
[1]
[3]
[2]
F-4-113
4-46