10-3-4. Wiring Connection

Connecting cable
Wiring the connecting cable can be carried out
without removing the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward
you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (or as according to
local regulations/codes) into the pipe hole on the
wall.
4. Pull the connecting cable through the cable slot
on the rear panel so that it protrudes about 15 cm
out of the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
Make a loop with the earth wire under the
terminal block and secure it with the earth screw.
6. Tightening torque: 1.2 N•m (0.12 kgf•m)
7. Secure the connecting cable with the cord clamp.
8. Attach the terminal cover and moving panel on
the indoor unit.
CAUTION
Be sure to refer to the wiring system diagram
labelled inside the front panel.
Check local electrical regulations for any
specifi c wiring instructions or limitations.
Termin l cov r
Screw
Screw
Cord clamp
Connecting cable
about 15 cm
10 mm
NOTE:
Connecting cable (Indoor unit/outdoor unit)
Wire type: H07RN-F or 60245IEC66 (1.0 mm²)
– 57 –
Terminal block
Earth wire
Connecting cable
Fig. 10-3-6
Terminal block
Earth wire(loop)
Earth screw
Fig. 10-3-7
Fig. 10-3-8
Earth line
110 mm
10 mm
50 mm
Fig. 10-3-9