Specifications Of Electrical Parts - Toshiba RAS-M10PKVP-E Service Manual

Split type, indoor & outdoor unit
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

6.
6-1. Indoor Unit
RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E
No.
Parts name
1
Fan motor (for indoor unit)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCj-sensor)
5
Humidity sensor
6
Louver motor (Right, Left, Horizontal)
7
Louver motor (Moving panel)
6-2. Outdoor Unit
RAS-M18UAV-E
No.
Parts name
SC coil (Noise fi lter)
(L03)
1
SC coil (Noise fi lter)
(L01)
2
DC-DC transformer
3
Fan motor (For outdoor)
4
Relay (4-way valve)
5
Relay (Power relay)
Discharge temp. sensor
6
(TD-sensor)
Outside air temp. sensor
7
(TO-sensor)
TGa-sensor
8
(Heat pump models)
TGb-sensor
9
(Heat pump models)
Evaporator temp. sensor
10
(TE-sensor)
Suction temp. sensor
11
(TS-sensor)
12
Terminal block (9P)
13
Fuse
14
Electrolytic capacitor
15
IGBT (Q200~Q205)
16
Compressor
17
Compressor thermo.
18
Rectifi er (DB01, DB02)
19
IGBT (Q404)
20
Reactor (Main)
21
Reactor (Sub)
22
Coil for P.M.V.
23
Coil for 4-way valve

SPECIFICATIONS OF ELECTRICAL PARTS

Model name
ADR2520-R15TB
ADR25H-200R8TB
SWT-72
ICF-140-43-4R
G5NB-1A
G4A-1A-PE
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
For protection of switching power source (F03)
For protection of inverter input overcurrent (F01) AC 250V, 25A
For protection of power source
LLQ2G761KHUATF
GT20J321
DA130A1F-25F
US622KXTMQO
D25XB60
GT40Q321
CH-57-FC, CH-57-Z-T
CH-76-TM1, CH-43-Z-T
CAM-MD12TF
STF-01AJ502E1
Type
ICF-340-30-4
DC 280–340 V, 30 W
( – )
10 kΩ at 25°C
( – )
10 kΩ at 25°C
( – )
10 kΩ at 25°C
C7-M3R-TC2
31 kΩ, 60 % RH
MP24Z3N
Output (Rated) 1 W, 16 poles, DC12 V
MP24Z4N
Output (Rated) 1 W, 16 poles, DC12 V
AC 250V, 20A, 0.15mH
AC 250V, 20A, 0.88mH
Primary side DC 280V Secondary side:
7.5V × 1, 13V × 126.5V × 3, 16V × 1, 15V × 1
DC 140V, 43W
Coil: DC 12V, Contact: 3A, AC250V
Coil: DC 12V, Contact: 20A, AC250V
1,905kΩ (120°C)
10kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
AC 250V, 20A
AC 250V, 3.15A
AC 250V, 6.3A
DC 400V, 760μF
600V, 20A
3 phases, 4 poles, 1,100W
OFF: 125 ± 4°C, ON: 90 ± 5°C
Diode: 600V, 25A
IGBT: 1200V, 40A
L = 10mH, 16A
L = 10mH, 1A
DC 12V
AC 220 – 240V
– 21 –
Specifi cations
Rating