Toshiba RAS-M10PKVP-E Service Manual page 106

Split type, indoor & outdoor unit
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

No.
Part name
Electronic
1. Detachment
i
expansion
valve coil
2. Attachment
<Handling precaution>
When handling the parts, do not pull the leads.
When removing the coil from the valve body, use your
hand to secure the body in order to prevent the pipe
from being bent out of shape.
Fan guard
1. Detachment
j
2. Attachment
Procedure
1) Perform step 1 in b, all the steps in c and 1 in
e.
2) Remove the coil by pulling it up from the
electronic control valve body.
1) When assembling the coil into the valve body,
ensure that the coil anti-turn lock is installed
properly in the pipe.
1) Perform work of item 1 of b.
2) Remove the front cabinet, and put it down so that
fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent fl aw to the product.
3) Remove the hooking claws by pushing minus
screwdriver according to the arrow mark in the
right fi gure, and remove the fan guard.
1) Insert claws of the fan guard in the holes of
the front cabinet. Push the hooking claws
(9 positions) by hands and fi x the claws.
All the attaching works have completed.
Check that all the hooking claws are fi xed to
the specifi ed positions.
– 106 –
Remarks
Coil
anti-turn
lock
Coil anti-turn
lock position
Coil inserting
position
Minus screwdriver
Hooking claw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m13pkvp-eRas-m18uav-eRas-m16pkvp-e

Table of Contents