Toshiba RAS-M10PKVP-E Service Manual page 96

Split type, indoor & outdoor unit
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

12-1-4. Microcomputer P.C. Board
1) Remove the electric parts cover screw.
2) Detach the metal electric parts cover.
3) Disconnect the connectors from the P.C. board.
4) Disconnect the solderless terminals from the P.C.
board.
5) Remove the P.C. board.
Electric parts cover detached
Screw
Electric parts
cover
Indoor P.C. board
Claw (2 locations)
Fig. 12-1-6
Claw
Sub-base
(2 locations)
12-1-5. Louver
1) Open the moving panel, and support it with the
panel support.
2) Open the vertical air fl ow louver.
3) Insert a fl athead screwdriver into the gap of the
louver fi xture on the right and left ends of the
vertical air fl ow louver, and turn in the counter-
clockwise direction to remove.
Horizontal air flow louvers
Removing the
louver fixture
(Left side)
4) After pushing in the right and left connector joints,
remove the vertical air fl ow louvres.
Remove the centre joint and bend the louver
downward.
Remove the right side joint fi rst, and then,
remove the left side joint.
Left side joint
– 96 –
Louver fixture
Air flow louver
Flathead screwdriver
Removing the
louver fixture
(Right side)
Fig. 12-1-7
Centre
Right side joint
joint
Fig. 12-1-8