Mounting the installation plate directly on a
wall
1. Securely fi t the installation plate onto the wall by
screws with the upper and lower catches.
2. To mount the installation plate on a concrete wall
use anchor bolts. Drill the anchor bolt holes as
illustrated in the above fi gure.
3. Place the level at the top end of the installation
plate, and check that the plate is horizontal.
CAUTION
When installing the installation plate with
mounting screws, do not use anchor bolt holes.
Otherwise the unit may fall down and result in
personal injury and property damage.
NO
OK
NO
GOOD
GOOD
Fig. 10-3-4
5 mm dia. hole
Clip anchor
(local parts)
Fig. 10-3-5
CAUTION
Failure to securely install the unit may result in
personal injury and/or property damage if the
unit falls.
In case of block, brick, concrete or similar type
walls, drill 5 mm dia. holes in the wall.
Insert clip anchors for the [5] mounting screws.
NOTE:
Install the installation plate using between 4 to 6
mounting screws, making sure all four corners are
secure.
Anchor bolt
Projection
15mm or less
[5] Mounting screw
Ø4 × 25L
– 56 –

10-3-3. Electrical Work

1. The supply voltage must be the same as the
rated voltage of the air conditioner.
2. Prepare a power source for the exclusive use of
the air conditioner.
NOTE:
Wire type: H07RN-F or 60245IEC66 (1.0 mm²)
Make sure the wire length is suffi cient before
performing wiring work.