2416 - xx
Video noise pattern
test failed
2418 - xx
ECG/VGC memory test
failed
---------------------------------------------------------------------------
Error
Code
Description
---------------------------------------------------------------------------
2419 - xx
ECG/VGC ROM
checksum test failed
2421 - xx
ECG/VGC 640 x 200
graphics mode test
failed
2422 - xx
ECG/VGC 640 x 350 16
color set test failed
2423 - xx
ECG/VGC 640 x 350 64
color set test failed
2424 - xx
ECG/VGC monochrome
text mode test failed
2425 - xx
ECG/VGC monochrome
graphics mode test
failed
2431 - xx
640 x 480 graphics
test failure
2432 - xx
320 x 200 graphics
(256 color mode) test
failure
2448 - xx
Advanced VGA
Controller test
failed
2451 - xx
132-column Advanced
VGA test failed
2456 - xx
Advanced VGA 256
Color test failed
---------------------------------------------------------------------------
2458 - xx
Advanced VGA BitBLT
test
2468 - xx
Advanced VGA DAC test
2477 - xx
Advanced VGA data
path test
2478 - xx
Advanced VGA BitBLT
test
2480 - xx
Advanced VGA Linedraw
test
Recommended Action
The following steps apply to 2402 - xx
through 2456 - xx error codes:
1. Run the Configuration and
Diagnostics Utilities.
2. Replace the monitor and retest.
3. Replace the video board and retest.
The following steps apply to 2458 - xx
through 2480 - xx error codes:
1. Replace the video board.
2. Replace the system board and retest.