Compaq Prolinea Family Maintenance & Serice Manual page 36

Table of Contents

Advertisement

1205 - xx
Auto answer Test
failed
1210 - xx
Modem Direct Connect
Test failed
===========================================================================
Table 2-9. Hard Drive Test Error Codes
===========================================================================
Error
Code
Description
===========================================================================
1701 - xx
Hard drive format
test failed
1702 - xx
Hard drive read test
failed
1703 - xx
Hard drive write/read
/compare test failed
1704 - xx
Hard drive random
seek test failed
1705 - xx
Hard drive controller
test failed
1706 - xx
Hard drive ready test
failed
1707 - xx
Hard drive
recalibration test
failed
1708 - xx
Hard drive format bad
track test failed
1709 - xx
Hard drive reset
controller test
failed
1710 - xx
Hard drive park head
test failed
1715 - xx
Hard drive head
select test failed
1716 - xx
Hard drive
conditional format
test failed
1717 - xx
Hard drive ECC *
test failed
1719 - xx
Hard drive power mode
test failed
1724 - xx
Network preparation
test failed
Recommended Action
The following steps apply to 1701 - xx
through 1736 - xx:
1. Run the Configuration and
Diagnostics Utilities and verify
drive type.
2. Replace the hard drive signal and
power cables and retest.
3. Replace the hard drive controller
board and retest (if applicable).
4. Replace the hard drive and retest
(if applicable).
5. Replace the system board and retest.

Advertisement

Table of Contents
loading