Nikon D300 Repair Manual page 105

Hide thumbs Also See for D300:
Table of Contents

Advertisement

Items
Standby (idle) /
consumed current
Operation time /
consumption current
accumulated
Rush current
Clock accuracy
BC level
Bulb battery life
Additional Page
Judgment standard
Main SW / OFF: 150 μA or less
(Do NOT press any operational buttons.)
Main SW / ON (Half-release timer: OFF): 150 μA or less
Main SW / ON (Half-release timer: ON): 220 m A or less
Main SW / ON (Illumination: ON): 250 mA or less
Main SW / ON (TFT ON): 300 mA or less
During live view: 770 mA or less
Lens scan
AF50/.8  Operation time: 000 ms or less 
    Consumption current accumulated: 500 mAsec or less
AF70-20/4-5.6 Operation time: 2000 ms or less
    Consumption current accumulated: 800 mAsec or less
 
Preview
Operation time: 50ms or less
    Consumption current accumulated: 00 mAsec or less
Release without memory card 
Operation time: 80 ms or less
     Consumption current accumulated: 200 mAsec
Shooting operation: 4.0A or less
Difference par month: ��30 seconds (20℃)
Level 0 5 lights up Charge remaining: 80 ~ 00%
Level  4 lights up Charge remaining: 60 ~ 79%
Level 2 3 lights up Charge remaining: 40 ~ 59%
Level 3 2 lights up Charge remaining: 20 ~ 39%
Level 4  light up Charge remaining:  ~ 9%
Level 5  light blinking Charge remaining: 0%
When special Li-ion is used: 1 and a half hours or more
- R4 ・    -
logo Q0310 forGraphic
070509 Gdesign ito
INC
VBA20001-R.3720.A
Remarks
Constant-voltage
power source (5A or
more)
Battery tool
(J623)
Ammeter
AF50/.4
EV2
Constant voltage
power source (5A or
more)
Battery tool
(J620)
Special tool
Oscilloscope
LV2
Constant voltage
power source
Battery tool
(J620)
Special tool
Oscilloscope
LV2
Wave clock
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Clock
Remote wire
サービス
計画課
Feb.st.2008

Hide quick links:

Advertisement

Table of Contents
loading