Waste Toner Hv Contact Assembly Removal - Lexmark X746de Service Manual

Hide thumbs Also See for X746de:
Table of Contents

Advertisement

Waste toner HV contact assembly removal

Disconnect the transfer module cable (A).
1.
2.
Press the two tabs (B) to release the front access cover assembly.
Press the two tabs (C) on either side of the transfer module, and lift out the transfer module.
3.
Note: Leave the photoconductor units on the transport belt when removing.
Warning: To avoid damaging the photoconductor drum, place the transfer module with the
photoconductor units on a clean surface. Never expose the photoconductor units to light for a prolonged
period of time. Place a clean, dry cloth over the transfer module and photoconductor units until they are
required.
Remove the left cover. See
4.
B
C
"Left cover removal" on page
A
4-24.
Repair information
7526
Previous
Next
Go Back
4-201

Advertisement

Table of Contents
loading

This manual is also suitable for:

X748dteX748de

Table of Contents