3 6
Section C - Performance Data
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A with Run/Start Capacitor
Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 of cycle)
Wattage (last 1/3 of cycle)
Amps (running)
Base Voltage
Cabinet Size
23'
Electronic Timer – (ADC) Defros 24 minutes every 6 to 96 hours of compressor run time.
Watts
2.8
Electrical
Thermostat
Heater Wattage
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
1
2
3
4
PERFORMANCE DATA
85°F (18°C) Ambient
32 TO 40%
0° TO 4°F
-18° to -16°C
34° TO 39°F
1° to 4°C
5 to 12 psig
34 to 83 kPa
-2 to 2 psig
-14 to 14 kPa
90 to 115 psig
621 to 793 kPa
120 to 150
1.0 to 1.4
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cut-In
25°F
-4°C
CONDENSER FAN MOTOR
RPM
950 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
115 vac (127 vac max)
Opens at 48°F (9°C)
85
Wire Color
Green/Yellow
Yellow
Black
Light Blue
90°F (32°C) Ambient
55 TO 65%
-1° TO 3°F
-18° to -16°C
34° TO 39°F
1° to 4°C
5 to 12 psig
34 to 83 kPa
-2 to 2 psig
-14 to 14 kPa
130 to 155 psig
896 to 1069 kPa
130 to 160
1.1 to 1.5
115 vac (127 vac max)
Heater
Cut-Out
Watts
47°F
450
8°C
Amps
.1 Running
Closes at 15°F (-9°C)
Connects to:
Ground
Water Valve
Line
Neutral
Ohms
30

Hide quick links: