Electrolux Side by Side Refrigerator Service Manual page 137

Hide thumbs Also See for Side by Side Refrigerator:
Table of Contents

Advertisement

130
Section H - Water System
L1
Dispenser
Actuator
Switch
Ice Maker Fill Switch
VOLTAGE READINGS AT GREEN COIL OF SECONDARY VALVE
When Ice Maker is Filling:
Voltage at Outlet
120 VAC
100 VAC
100 - 120 VAC
VOLTAGE READING AT YELLOW COIL OF SECONDARY VALVE
When Filling A Glass With Water:
Voltage at Outlet
120 VAC
100 VAC
100 - 120 VAC
VOLTAGE READING AT COIL OF PRIMARY VALVE
When Ice Maker is filling:
Voltage at 0utlet
120 VAC
100 VAC
100 - 120 VAC
100 - 120 VAC
NOTE : You must remember that with the current flowing to the Primary Valve Coil through the Diode,
you are getting 30 cycle instead of 60 cycle current at the coil of the Primary Valve. Because of this,
your volt meter will only read about 1/2 the voltage that is going to the coil. The change in the cycle of
current does not effect the efficiency of an electromagnetic coil.
Water/Ice
Selector Switch
on Dispenser
Fill Solenoid
Single Coil Valve
Ice
Water
Diodes
Ice Maker Fill Solenoid Dual Coil Valve
Voltage at Coil
100 ± 10% VAC
Normal (95 to 105 VAC)
85 ± 10% VAC
Normal (95 to 105 VAC)
20 - 76 VAC
Bad connection, Fill Switch, or Heater in Ice Maker.
Voltage at Coil
119 ± 10% VAC
Normal
99 ± 10% VAC
Normal
0 - 90 VAC
Bad connection or bad Fill Switch
Voltage at Coil
50 ±10% VAC
Normal
48 ± 10% VAC
Normal
10 - 43 VAC
Bad connection, Fill Switch, or Heater in Ice Maker
Less than 10 VAC
Open Diode (if current is normal at secondary coil)
Figure H10
N
Water Fill Solenoid
Dual Coil Valve
Yellow
Green