Installation Steps - B&B Electronics e-Linx EIRP610-2SFP-T User Manual

Table of Contents

Advertisement

3.1 Installation Steps

1. Unpack the Industrial switch
2. Check that the DIN-Rail clip is screwed onto the Industrial switch. If the DIN-Rail clip
is not screwed onto the switch, refer to the DIN-Rail Mounting section for DIN-Rail
clip installation. If wall or panel mounting is preferred, refer to Wall or Panel Mount
Plate Mounting section for plate installation.
3. To hang the switch on DIN-Rail track or to wall/panel mount the switch please refer to
the appropriate section for installation instructions.
4. Power on the Industrial switch. Please refer to the Wiring the Power Inputs section for
knowing the information about how to wire the power. The power LED on the Industrial
switch will light up. Please refer to the LED Indicators section for indication of LED
lights.
5. Prepare the twisted-pair, straight through Category 5 or above cable for Ethernet
connection.
6. Insert one end of RJ-45 cable (category 5 or above) into the switches Ethernet port (RJ-
45 port) and the other side of the RJ-45 cable into the network device's Ethernet port
(RJ-45 port), ex: Switch PC or Server. The LED on the Industrial switch will light up
when the cable is connected with the network device. Please refer to the LED
Indicators section for LED light indication.
[NOTE]
Make sure that the connected network devices support MDI/MDI-X. If they do not
support MDI/MDI-X a crossover cable may be required.
7. When all connections are set and LED lights all show in normal, the installation is
complete.
12
Chapter 3 Hardware Installation
Manual Documentation Number EIRP610-2SFP-T – 0912m
Hardware Installation
www.bb-elec.com
www.bb-europe.com

Advertisement

Table of Contents
loading

Table of Contents